Schaublin_Catalogue
Page - Seite 8.6
Clamping forces for collets
The force Fy tends to tip the work piece out of the collet bore, when the clamping length is short (L1 < D1). To prevent this you must increase the axial force Ft by the factor β .
L
L
2
1
½ F
µ
n
2 α, µ
M
1
x
D
2
F
D
t
1
F
x
F
y
½ F
n
2
µ for work pieces in steel : 0.3 0.05 1 µ = = ÷
2M
2 µ β s
2
x
=
+
+
F
F
(tan α
)
1 µ
t
x
D
1
0.6 with serrated bore 0.3 0.4 with grooved bore 0.2 0.3 with smooth bore 0.05 2 ÷ ÷ ÷
1.5 1.2 s ÷ =
Influence of F y in relation with the distance to the collet L 2
12
10
8
β
6
4
2
0
0.5 1 1.5 2 2.5 3 3.5 4
/D 1
L 2
Copyright © 2017 SCHAUBLIN S.A., All Rights Reserved www.schaublin.ch 476-4800 Edition 01/2017
Made with FlippingBook HTML5